loader image

Follow us on

+971 (0)4 267 4540

Cat 6A S/FTP PVC Cable

Data Sheet

Get Quote

Category 6A S/FTP PVC cables are designed to deliver a robust standards based performance ensuring optimum bandwidth for today’s high speed network applications. The cable is designed to support horizontal networking applications over distances up to 100 meters.

Each Category 6A S/FTP PVC exceed the minimum specified performance for Category 6A S/FTP cables and support all CLASS EA applications as defined within ISO/IEC 11801 (2nd Edition): 2010 such as 10GBASE-T (Gigabit Ethernet), 2G FCBASE-T, 4G FCBASE-T and 1000BASE-T (Gigabit Ethernet).

  • RoHS compliant 2002/95/EC
  • REACH / SVHC compliant regulation (EC) No. 1907/2006

     Pair color code:

  • Pair 1:White/Blue, and Blue
  • Pair 2:White/Orange, and Orange
  • Pair 3:White/Green, and Green
  • Pair 4:White/Brown, and Brown
CONSTRUCTION
 
Conductor23AWG solid copper
InsulationExpanded Polyethylene
Cable8 insulated wires formed into 4 pairs. Each pair is individually screened with an aluminised polyester tape. (The aluminium side of the tape aces outwards and is in continuous contact with the tinned copper drain wire).
ScreenAn aluminised polyester tape screen applied with a 15% minimum overlap (The aluminium side is in continuous contact with the tinned copper drain wire.)
Sheath Material Polyvinyl Chloride (PVC)
Sheath Color

Orange ;

Diameter7.1mm (± 0.3mm)
Electrical properties at 20ºC 
Nom. mutual capacitance≦5.6 nF/100m (@1kHz)
Pair to ground capacitance unbalance≦1600 pF/1Km
Nominal velocity of propagation74%
Max. delay skew45 ns/100m
Max. conductor DC resistance95 Ω/km (@ 20 ℃)
Max. conductor resistance unbalance2% (@ 20 ℃)
Min. insulation resistance5000 MΩ·m
Test voltage (d.c. for 1 minute) Conductor/Conductor1000V
Max. operating voltage – UL300 V
  
Mechanical Characteristics Temperature Range 
Operation-20°C to + 60°C
Installation0°C to +50°C
Storage-20°C to + 70°C
Maximum Tensile Force 
During Installation100N
Minimum Bend Radii 
Installation8 x Cable Diameter

 

TRANSMISSION LINE PERFORMANCE AT 20ºC

FREQUENCY MHZ
ATTENUATION DB/100M
NEXT DB
ACR MIN DB
PSNEXT MIN DB
ELFEXT MIN DB
PSELFEXT MIN DB
PSANEXT MIN DB
RETURN LOSS
11.895.093.295.068.065.0
43.866.362.566.358.055.076.523
105.960.354.460.350.047.072.525
208.455.847.455.844.041.069.525
62.515.048.433.448.434.131.164.521.5
10019.145.326.245.330.027.062.520.1
25031.129.38.239.322.019.056.517.3
50045.334.8-10.534.816.013.052.017.3

The Category 6A S/FTP PVC cable is manufactured and tested directly in accordance with the major industry standards:

  • ISO/IEC 11801 2nd Edition
  • ANSI/TIA 568-C.2
  • EN 50173
  • IEC 61156-5
  • EN 50288-3-1

Category 6S/FTP PVC cables exceed the requirements of:

  • IEC 60332-1-2
  • IEC 60754-2
  • IEC 61034
Description
Category 6A S/FTP PVC cables are designed to deliver a robust standards based performance ensuring optimum bandwidth for today’s high speed network applications. The cable is designed to support horizontal networking applications over distances up to 100 meters.

Each Category 6A S/FTP PVC exceed the minimum specified performance for Category 6A S/FTP cables and support all CLASS EA applications as defined within ISO/IEC 11801 (2nd Edition): 2010 such as 10GBASE-T (Gigabit Ethernet), 2G FCBASE-T, 4G FCBASE-T and 1000BASE-T (Gigabit Ethernet).

Features/ Benefits
  • RoHS compliant 2002/95/EC
  • REACH / SVHC compliant regulation (EC) No. 1907/2006

Pair color code:

  • Pair 1:White/Blue, and Blue
  • Pair 2:White/Orange, and Orange
  • Pair 3:White/Green, and Green
  • Pair 4:White/Brown, and Brown
Specifications
CONSTRUCTION
 
Conductor23AWG solid copper
InsulationExpanded Polyethylene
Cable8 insulated wires formed into 4 pairs. Each pair is individually screened with an aluminised polyester tape. (The aluminium side of the tape aces outwards and is in continuous contact with the tinned copper drain wire).
ScreenAn aluminised polyester tape screen applied with a 15% minimum overlap (The aluminium side is in continuous contact with the tinned copper drain wire.)
Sheath Material Polyvinyl Chloride (PVC)
Sheath Color

Orange ;

Diameter7.1mm (± 0.3mm)
Electrical properties at 20ºC 
Nom. mutual capacitance≦5.6 nF/100m (@1kHz)
Pair to ground capacitance unbalance≦1600 pF/1Km
Nominal velocity of propagation74%
Max. delay skew45 ns/100m
Max. conductor DC resistance95 Ω/km (@ 20 ℃)
Max. conductor resistance unbalance2% (@ 20 ℃)
Min. insulation resistance5000 MΩ·m
Test voltage (d.c. for 1 minute) Conductor/Conductor1000V
Max. operating voltage – UL300 V
  
Mechanical Characteristics Temperature Range 
Operation-20°C to + 60°C
Installation0°C to +50°C
Storage-20°C to + 70°C
Maximum Tensile Force 
During Installation100N
Minimum Bend Radii 
Installation8 x Cable Diameter

 

TRANSMISSION LINE PERFORMANCE AT 20ºC

FREQUENCY MHZ
ATTENUATION DB/100M
NEXT DB
ACR MIN DB
PSNEXT MIN DB
ELFEXT MIN DB
PSELFEXT MIN DB
PSANEXT MIN DB
RETURN LOSS
11.895.093.295.068.065.0
43.866.362.566.358.055.076.523
105.960.354.460.350.047.072.525
208.455.847.455.844.041.069.525
62.515.048.433.448.434.131.164.521.5
10019.145.326.245.330.027.062.520.1
25031.129.38.239.322.019.056.517.3
50045.334.8-10.534.816.013.052.017.3

The Category 6A S/FTP PVC cable is manufactured and tested directly in accordance with the major industry standards:

  • ISO/IEC 11801 2nd Edition
  • ANSI/TIA 568-C.2
  • EN 50173
  • IEC 61156-5
  • EN 50288-3-1

Category 6S/FTP PVC cables exceed the requirements of:

  • IEC 60332-1-2
  • IEC 60754-2
  • IEC 61034

Related Products

Need Help? Chat with us